Get quotes

Free calculator, nothing to sign up for

Roof vent area calculator

Give the area of the ceiling under the roof: the tool works out the net free vent area a common building code rule of thumb asks for, splits it between the eaves and the top of the roof, and counts how many soffit strips, round vents, turbines, vent tiles or metres of ridge vent make up each half.

A slotted aluminium vent strip in a white soffit board under the eaves of a face brick house, with a whirlybird on the tiled roof above
Calculator1:300Vent area to ceiling area. Half low, half high
Vent area for a roof spaceruns in your browser
Ceiling area
-
Net free area needed
-
Intake, low
-
Exhaust, high
-
Intake vents
-
Exhaust vents
-

Total = ceiling area / 150 or / 300, the common building code rule of thumb. 50% goes high by default (the 1:300 rule asks for 40 to 50% high and the rest at the eaves); 1:150 is the figure when the vents cannot be balanced that way. Free areas are makers' published figures; a turbine counts as its round throat. If a grille shows only its outside size, take about 60% of width x height as its free area. The bars show the exhaust need in each type.

How big must the vents in a roof space be? The usual answer is a ratio of open vent area to ceiling area. This calculator applies it, splits the area between the eaves and the top of the roof, and turns each half into real vents. Read why both halves matter on roof ventilation, compare intake options on eave vents and exhaust on ridge vents, or count turbines on their own with the whirlybird calculator.

How the rule works

A common overseas building code asks for 1 m² of net free vent area per 150 m² of ceiling, or per 300 m² when balanced: 40 to 50% high on the roof, the rest at the eaves. Roofers here use it as a guide.

Take a single storey house in Pretoria with 180 m² under the roof. At 1:300 it needs 0.6 m², which is 600,000 mm². Half goes low: 300,000 mm² is about 30 m of slotted soffit strip. Half goes high: 300,000 mm² is just over four 300 mm turbine throats, so five turbines, or about 30 vent tiles, or about 60 m of ventilated dry ridge. Most houses end up with a mix.

Net free area is not the hole size

Mesh and louvres block part of every vent, so makers publish a net free area: a round 70 mm push in soffit vent about 2,000 mm², a slotted soffit strip 10,000 mm² per metre, a vent tile about 10,000 mm², a ventilated dry ridge on tiles 5,000 mm² per metre and a continuous ridge vent on sheeting around 32,000 mm² per metre. A turbine is counted as its round throat. If a grille only shows its outside size, take about 60% of width x height. Or type your product's own figure.

Putting the vents in the right place

  • Intake goes low, along both sides of the building, so air crosses the whole roof space.
  • Exhaust goes high, near the ridge, where the hottest air collects.
  • Keep ceiling insulation back from the eave gap, or the intake is blocked.

Frequently asked questions

Should I use 1:150 or 1:300?
Use 1:300 when about half can go low and half high, the usual case. Use 1:150 when the openings can only go at one level.
My eaves are open. Do I still need eave vents?
Open eaves already let air in, with birds and insects. A roofer can tell you whether a mesh strip is enough or more intake is needed.
Does this rule work for a factory or a hall?
It is for roof spaces over a ceiling. A shed open to the sheets is sized on volume and use: try the air changes calculator.
Who will quote me for the vents and the fitting?
Roofing suppliers, ventilation suppliers and roofers that work in your area quote you directly after one request. We are a request service only and sell or fit nothing ourselves.

More calculators

Request roof ventilation quotes

Fill in the request: what you need, the area under the roof or the size of the space, the roof covering and the problem you want solved. Roofing and ventilation suppliers, roofers and installers that serve your area quote you directly. It is free and there is no obligation.

Request 8223Roof Ventilation

1The job

2The roof (optional, it helps the quote)

Your roof, in sectionrule of thumb

-
-
-
-
-
-
Estimate
-

A rule of thumb for the request, not a supplier's quote.

3The problem, finish and timing

4Your list (optional)

  1. L01
  2. L02
Up to 12 lines: units, bases, vents, labour.
Needs and options

5Your details

Free and no obligation. By sending you agree that we may share your request with suitable suppliers, roofers and installers. See our privacy policy.

Get free quotes