Free calculator, nothing to sign up for

Air changes calculator

Give the length, width and height of a warehouse, workshop, hall, kitchen or poultry house and pick its use: the tool starts from an air change rate published for that use, works out the airflow in m³/h, m³/s and l/s, and counts the fans of a capacity you type or the turbines of a size you choose.

A row of large grey wall mounted extractor fans with guards high on the end wall of a steel warehouse, with turbines on the roof
Calculator6 ACHWarehouse starting figure. Volume x air changes
Airflow from air changesruns in your browser
Volume
-
Air changes an hour
-
Airflow needed
-
The same in m³/s and l/s
-
Fans of that size
-
Or turbines
-

Airflow = length x width x height x air changes an hour. Each use starts at a figure inside the ranges published engineering tables give for it (the gym figure is ours); change it to suit. Fans: use the airflow on the fan's own data sheet at the pressure it will work against. Turbines: makers' test figures at the wind you pick; on a still day they move far less, so heat or fumes that must go every hour need fans. Intake openings low down must match the exhaust.

Ventilation for a whole building is sized on air changes: how many times an hour the full volume of air is replaced. A storeroom needs a few, a hot factory or a busy kitchen many more. This calculator multiplies the volume by a starting figure for the use you pick, then tells you what that airflow means in fans or turbines. Read about the equipment on industrial extractor fans and industrial turbine ventilators, or weigh them up on turbine ventilator vs exhaust fan.

The sum and a worked example

Airflow in m³/h = length x width x average height x air changes an hour. Divide by 3,600 for m³/s, or by 3.6 for l/s.

A Germiston warehouse 60 x 30 m with an average height of 8 m holds 14,400 m³. At 6 air changes, inside the published range of 2 to 10 for storage, it needs 86,400 m³/h, or 24 m³/s. Fans that each move 10,000 m³/h on their data sheet: 9 of them. Turbines with a 600 mm throat: one maker's tested figure is about 3,350 m³/h in an 8 km/h breeze, which would mean 26; in a moderate wind fewer will do, and the tool shows that too.

Where the starting figures come from

Each use opens on a figure taken from published engineering tables: a house roof space 12, a workshop 8, a warehouse 6, a light factory 10, a factory with heat, fumes or moisture 20, a laundry 12, a commercial kitchen 30, a poultry house 8, a hall or church 8, an office 5. The tool shows the published range beside it. No table we found covers a gym, so its 6 is our own starting point. Change any figure to what your engineer, poultry adviser or fan supplier recommends.

Fans or turbines

  • Turbines cost nothing to run but follow the wind; on a still night they move a fraction of their rating.
  • Fans deliver the airflow on demand and can be switched by a thermostat, but need wiring by an electrician and power during load shedding.
  • Either way, the building needs low openings, louvres or a roller door to let the same amount of air in.

Frequently asked questions

What height do I use for a pitched roof shed?
The average: the eaves height plus half the rise to the ridge. For a shed 6 m at the eaves and 10 m at the ridge, use 8 m.
Is the fan's rated airflow what I will get?
Not always. A fan's rating is at a stated pressure, and louvres, ducts and guards reduce it. Use the figure from the fan curve at the pressure your installer expects.
Are more air changes always better?
More air cools people and clears fumes, but costs power and adds noise. Check the figure with the supplier.
Who will quote on fans or turbines for my building?
Ventilation contractors, fan suppliers, roofers and electricians that serve your area quote you directly after one request. We are not a supplier and install nothing.

More calculators

Request industrial extractor fans quotes

Fill in the request: what you need, the area under the roof or the size of the space, the roof covering and the problem you want solved. Roofing and ventilation suppliers, roofers and installers that serve your area quote you directly. It is free and there is no obligation.

Request 7082Industrial Extractor Fans

1The job

2The space (optional, it helps the quote)

Your space and its airrule of thumb

-
-
-
-
-
-
Estimate
-

A rule of thumb for the request, not a supplier's quote.

3The problem, finish and timing

4Your list (optional)

  1. L01
  2. L02
Up to 12 lines: units, bases, vents, labour.
Needs and options

5Your details

Free and no obligation. By sending you agree that we may share your request with suitable suppliers, roofers and installers. See our privacy policy.

Get free quotes